🚚 Free Worldwide Shipping on All Orders!Shop Now
HomeStore

Apollo 4A Series Reduced Pressure Backflow Preventer | 3/4 in. & 1 in.

Product image 1

Apollo 4A Series Reduced Pressure Backflow Preventer | 3/4 in. & 1 in.

Apollo 4A Series Reduced Pressure Backflow Preventer | 3/4 in. & 1 in.

Apollo 4A Series Reduced Pressure Backflow Preventer

Brand: Apollo (Conbraco) | SKUs: 4A204A2F, 4A205A2F

Product Overview

The Apollo 4A Series reduced pressure principle backflow preventer is designed to help isolate potable water from a non-potable downstream system in approved high-hazard applications. It uses two independently operating check modules with an intermediate relief valve. If pressure conditions prevent the checks from maintaining the required separation, the relief valve can discharge water from the zone between them rather than allowing a backflow condition to move toward the potable supply.

This listing includes 3/4 in. and 1 in. bronze assemblies with lead-free shut-off ball valves and test cocks. The modular check design supports in-line inspection and service. Because an RPZ can intentionally discharge during operation or a fault condition, the installation must provide suitable drainage, air-gap protection, access, and freeze protection. Confirm that an RPZ is required for the hazard level and that the selected size and connection configuration match the system.

Key Features:

  • Reduced pressure principle backflow assembly
  • Protection against backsiphonage and backpressure in approved applications
  • 3/4 in. and 1 in. sizes
  • Bronze body
  • Lead-free shut-off ball valves
  • Modular check cartridges and accessible test cocks

Common Uses:

  • Irrigation systems requiring RPZ protection
  • Boiler or mechanical makeup-water lines where approved
  • Commercial and residential cross-connection control
  • Replacement of compatible reduced-pressure assemblies

Technical Specifications:

  • Models: 4A204A2F, 4A205A2F
  • Sizes: 3/4 in. and 1 in.
  • Maximum Working Pressure: 175 PSI
  • Temperature Range: 33-180°F
  • Body: Bronze
  • Approvals: ASSE 1013, CSA B64.4, NSF/ANSI 61 and 372, USC FCCC&HR

Installation Notes:

Install horizontally with required clearances, drainage, air gap, testing access, and freeze protection. Follow local cross-connection-control requirements.

FAQ:

Why can an RPZ discharge water?
The relief valve opens when pressure conditions in the intermediate zone require it.

Are shut-off valves included?
Yes. The A2F configuration includes shut-off valves and test cocks.

Why Buy From Big Frog Supply?

Big Frog Supply provides clear product information, helpful support, and convenient online ordering for backflow-prevention equipment.

Select Size
From $297.99
Apollo 4A Series Reduced Pressure Backflow Preventer | 3/4 in. & 1 in.
$297.99

Product Information

Shipping & Returns

Description

Apollo 4A Series Reduced Pressure Backflow Preventer

Brand: Apollo (Conbraco) | SKUs: 4A204A2F, 4A205A2F

Product Overview

The Apollo 4A Series reduced pressure principle backflow preventer is designed to help isolate potable water from a non-potable downstream system in approved high-hazard applications. It uses two independently operating check modules with an intermediate relief valve. If pressure conditions prevent the checks from maintaining the required separation, the relief valve can discharge water from the zone between them rather than allowing a backflow condition to move toward the potable supply.

This listing includes 3/4 in. and 1 in. bronze assemblies with lead-free shut-off ball valves and test cocks. The modular check design supports in-line inspection and service. Because an RPZ can intentionally discharge during operation or a fault condition, the installation must provide suitable drainage, air-gap protection, access, and freeze protection. Confirm that an RPZ is required for the hazard level and that the selected size and connection configuration match the system.

Key Features:

  • Reduced pressure principle backflow assembly
  • Protection against backsiphonage and backpressure in approved applications
  • 3/4 in. and 1 in. sizes
  • Bronze body
  • Lead-free shut-off ball valves
  • Modular check cartridges and accessible test cocks

Common Uses:

  • Irrigation systems requiring RPZ protection
  • Boiler or mechanical makeup-water lines where approved
  • Commercial and residential cross-connection control
  • Replacement of compatible reduced-pressure assemblies

Technical Specifications:

  • Models: 4A204A2F, 4A205A2F
  • Sizes: 3/4 in. and 1 in.
  • Maximum Working Pressure: 175 PSI
  • Temperature Range: 33-180°F
  • Body: Bronze
  • Approvals: ASSE 1013, CSA B64.4, NSF/ANSI 61 and 372, USC FCCC&HR

Installation Notes:

Install horizontally with required clearances, drainage, air gap, testing access, and freeze protection. Follow local cross-connection-control requirements.

FAQ:

Why can an RPZ discharge water?
The relief valve opens when pressure conditions in the intermediate zone require it.

Are shut-off valves included?
Yes. The A2F configuration includes shut-off valves and test cocks.

Why Buy From Big Frog Supply?

Big Frog Supply provides clear product information, helpful support, and convenient online ordering for backflow-prevention equipment.

Apollo 4A Series Reduced Pressure Backflow Preventer | 3/4 in. & 1 in. | Big Frog Supply