BackStop 10 Gallon Backstop Thermal Expansion Tank (Almond w/ 3/4" SS System Connection)
Product Overview
The BackStop 12-A110 is a 10-gallon precharged thermal expansion tank for compatible closed potable-water systems. When water is heated, its volume increases. In a system where a check valve, pressure-reducing valve, or backflow device prevents that expanded volume from moving back toward the supply, pressure can rise rapidly. The tank provides a sealed air cushion that accepts the expanded water and helps keep system pressure within the intended operating range.
A fixed butyl diaphragm separates the water from the precharged air chamber, while an FDA-grade polypropylene liner helps prevent water from contacting the carbon-steel shell. The almond-finished tank includes a 3/4 in. 304 stainless steel system connection, a 35 PSI factory precharge, and a 150 PSI maximum design pressure. Correct sizing and precharge adjustment depend on water-heater capacity, supply pressure, temperature, and system configuration.
Key Features:
- 10-gallon thermal expansion tank
- Fixed butyl diaphragm
- Polypropylene water-side liner
- Carbon-steel shell
- 3/4 in. stainless steel connection
Technical Specifications:
- Height: 20 in.
- Diameter: 11-1/2 in.
- Factory Precharge: 35 PSI
- Maximum Design Pressure: 150 PSI
- Maximum Design Temperature: 200°F
- Finish: Almond
Installation Notes:
Install on the cold-water side of a compatible water-heating system. Confirm tank sizing, support, orientation, precharge, and local plumbing requirements before installation.
FAQ:
Why is an expansion tank needed?
It absorbs expanded water volume in a closed system to help control pressure rise.
Should the precharge be checked?
Yes. It should be matched to the system's cold static pressure as directed by the manufacturer.
Why Buy From Big Frog Supply?
Big Frog Supply provides clear product information, helpful support, and convenient online ordering for water-heating and plumbing components.
Product Information
Product Information
Shipping & Returns
Shipping & Returns

BackStop 10 Gallon Backstop Thermal Expansion Tank (Almond w/ 3/4" SS System Connection)
BackStop 10 Gallon Backstop Thermal Expansion Tank (Almond w/ 3/4" SS System Connection)
Product Overview
The BackStop 12-A110 is a 10-gallon precharged thermal expansion tank for compatible closed potable-water systems. When water is heated, its volume increases. In a system where a check valve, pressure-reducing valve, or backflow device prevents that expanded volume from moving back toward the supply, pressure can rise rapidly. The tank provides a sealed air cushion that accepts the expanded water and helps keep system pressure within the intended operating range.
A fixed butyl diaphragm separates the water from the precharged air chamber, while an FDA-grade polypropylene liner helps prevent water from contacting the carbon-steel shell. The almond-finished tank includes a 3/4 in. 304 stainless steel system connection, a 35 PSI factory precharge, and a 150 PSI maximum design pressure. Correct sizing and precharge adjustment depend on water-heater capacity, supply pressure, temperature, and system configuration.
Key Features:
- 10-gallon thermal expansion tank
- Fixed butyl diaphragm
- Polypropylene water-side liner
- Carbon-steel shell
- 3/4 in. stainless steel connection
Technical Specifications:
- Height: 20 in.
- Diameter: 11-1/2 in.
- Factory Precharge: 35 PSI
- Maximum Design Pressure: 150 PSI
- Maximum Design Temperature: 200°F
- Finish: Almond
Installation Notes:
Install on the cold-water side of a compatible water-heating system. Confirm tank sizing, support, orientation, precharge, and local plumbing requirements before installation.
FAQ:
Why is an expansion tank needed?
It absorbs expanded water volume in a closed system to help control pressure rise.
Should the precharge be checked?
Yes. It should be matched to the system's cold static pressure as directed by the manufacturer.
Why Buy From Big Frog Supply?
Big Frog Supply provides clear product information, helpful support, and convenient online ordering for water-heating and plumbing components.
Original: $61.86
-65%$61.86
$21.65Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
Product Overview
The BackStop 12-A110 is a 10-gallon precharged thermal expansion tank for compatible closed potable-water systems. When water is heated, its volume increases. In a system where a check valve, pressure-reducing valve, or backflow device prevents that expanded volume from moving back toward the supply, pressure can rise rapidly. The tank provides a sealed air cushion that accepts the expanded water and helps keep system pressure within the intended operating range.
A fixed butyl diaphragm separates the water from the precharged air chamber, while an FDA-grade polypropylene liner helps prevent water from contacting the carbon-steel shell. The almond-finished tank includes a 3/4 in. 304 stainless steel system connection, a 35 PSI factory precharge, and a 150 PSI maximum design pressure. Correct sizing and precharge adjustment depend on water-heater capacity, supply pressure, temperature, and system configuration.
Key Features:
- 10-gallon thermal expansion tank
- Fixed butyl diaphragm
- Polypropylene water-side liner
- Carbon-steel shell
- 3/4 in. stainless steel connection
Technical Specifications:
- Height: 20 in.
- Diameter: 11-1/2 in.
- Factory Precharge: 35 PSI
- Maximum Design Pressure: 150 PSI
- Maximum Design Temperature: 200°F
- Finish: Almond
Installation Notes:
Install on the cold-water side of a compatible water-heating system. Confirm tank sizing, support, orientation, precharge, and local plumbing requirements before installation.
FAQ:
Why is an expansion tank needed?
It absorbs expanded water volume in a closed system to help control pressure rise.
Should the precharge be checked?
Yes. It should be matched to the system's cold static pressure as directed by the manufacturer.
Why Buy From Big Frog Supply?
Big Frog Supply provides clear product information, helpful support, and convenient online ordering for water-heating and plumbing components.